0086-731-88112150  sales@sandegroup.com

Home>Bomb Calorimeter>SDACM3100 Bomb Calorimeter

SDACM3100 Bomb Calorimeter

Application:

SDACM3100 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.

Most cost effective model with reliable results.
Analysis time is 15 min.
Sundy Sundy

Product description

Highlights:

①Accurate test result with large water quantity. Difference of jacket water temperature in each test is less than 0.1K.
②Support oxygen bomb air tightness examination, no complicated elevating mechanism and compressor.
③Strong data processing capability, statistics report and printing function; Capable of connecting with network and balance by RS232 interface.
④With exp

Application:
SDACM3100 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.

Highlights:

①Accurate test result with large water quantity. Difference of jacket water temperature in each test is less than 0.1K.
②Support oxygen bomb air tightness examination, no complicated elevating mechanism and compressor.
③Strong data processing capability, statistics report and printing function; Capable of connecting with network and balance by RS232 interface.
④With expert diagnostic, self-protection, self-diagnostic function
⑤Authentic test data, no software modification.

 

Specification:

Description SDACM3100
Analysis Time 15min
Temperature Resolution 0.0001K
Precision(RSD) ≤0.15%
Heat Capacity Stability ≤0.25% within three months
System Structure Benchtop
Conformance with Standard ASTM D5865, ASTM D240, ASTM D4809, ASTM E711,  ASTM D5468, AS 1038.5,BS EN 15400, BIS1350,ISO 1928, ISO 9831,ISO18125,GB/T 213,GB/T 30727
Test per Hour 2~4
Bomb volume 282ml
Calorimeter Type Isoperibol
Oxygen Filling Semi-automatic
Bomb Washing Manual
Max.Bomb pressure 20Mp
Bomb Identity No
Gas Requirement 99.5% Oxygen
Water Requirement Distilled  Water
Energy Measurement Range 0~50000J
Bucket Filling Automatic
Constant Volumetric Tank with Temp Control Device No
Independent Bucket and Jacket Water System No
Stirring Method Blade
Power Inverter No
Reproducibility based on analysis of 1g Benzoic Acid 0.15%
Average Temperature Increase 2℃
Temperature Measurement PT1000
Working Temperatures ≦32℃
Cooling method Automatic by water circulation
Network Yes
Power AC 220V(-15% +10%)50/60Hz
Max.Power 0.22kW
Dimension Main body: 600*500*425
Main Body Weight 65kg
Advance Calculation No
Analysis Report Yes
Statistics Report Yes
System Monitor Yes