1.Test procedures
Weigh a certain amount of perfluorohexyl sulfonic acid (reference materials), dissolve it in methanol, dilute it to an appropriate concentration, transfer a suitable volume of the solution onto the ignited quartz wool, perform the test according to the set procedure, and calculate the recovery rate.
2.Combustion conditions
Temperature: 1100℃ Oxygen: 0.4L/min
Argon(carrier): 0.2L/min Argon flow for humidification: 0.1L/min
Water vapor: 0.1mL/min Absorption solution: pure water
Combustion process
Step | Sample Introduction Time (s) | Distance (mm) | Retention Time (s) |
Step 1 | 17 | 170 | 100 |
Step 1 | 100 | 20 | 100 |
Step 3 | 100 | 15 | 100 |
Step 4 | 150 | 105 | 100 |
3.IC conditions
Analytical Column: IonPac AS19 2*250mm Guard Column: IonPac AG19 2*50mm
Eluent: EGC Ш KOH, 20mM, 0.25mL/min Column temp.: 30℃
Quantitative loop: 400ul Linear range:0.1-1mg/L
Detector: Dionex-ADRS 600
4.Test results

S/N. | CRM | Brand | Type | Theoretical Conc. (ug) | Measured Conc. (ug) | Recovery (%) |
1 | perfluorohexyl sulfonic acid | TM standard | Low conc. | 0.3 | 0.2938 | 97.93 |
2 | 0.2927 | 97.57 | ||||
3 | 0.2968 | 98.93 | ||||
4 | 0.2899 | 96.63 | ||||
5 | 0.2916 | 97.20 | ||||
6 | 0.2987 | 99.57 | ||||
Aver. | 0.2939 | 97.97 | ||||
RSD(%) | 1.12 | 1.12 | ||||
1 | perfluorohexyl sulfonic acid | TM standard | High conc. | 2 | 1.9278 | 96.39 |
2 | 1.9871 | 99.36 | ||||
3 | 1.9381 | 96.91 | ||||
4 | 1.9787 | 98.94 | ||||
5 | 1.9191 | 95.96 | ||||
6 | 1.9856 | 99.28 | ||||
Aver. | 1.9561 | 97.80 | ||||
RSD(%) | 1.59 | 1.59 | ||||