SDIS401 Infrared Sulfur Analyzer

Application:
Sundy SDIS401 Infrared Sulfur Analyzer can be used to determine the sulfur content in coal, coke, ash, biomass fuels and other combustibles in fields of power plants, coal mines, paper plants, metallurgy, petrochemical, steel factory etc.
描述一
Test reliable, cost-effective.
描述二
没有此类产品
Product description

Highlights

High precision.

①Unique designed high temperature combustion tube with secondary combustion function, make sure the samples combust thoroughly.

②Adopted high sensitivity and low drift infrared cell,the measurement result is stable and reliable.

 

Intelligent control.

①Easy-to-use Windows-based software,It only needs to click the mouse after weighing and placing the samples.

②Easy data handling, real time data can be transmitted by internal network.

③With Ethernet bus communication technology, one PC controls several analyzers.

④Capable of connecting with network and balance by RS232 interface.

 

Specifications:

Description

SDIS401

Test Method

Infrared Absorption

Sulfur Determination Range

0.01% - 50%(can be extended to 100%)

Standards

GB/T 25214-2010 ISO 19579:2006 ASTMD 4239-2012

Sulfur Resolution

0.001%

Analysis Time/sample

< 2 min

Preheating Time  

≤120min

Sample Loading

1

Sample Weight

80 – 500mg(100mg Recommended)

Furnace Temp

1250℃ - 1350℃

Heating Elements

Silicon Carbide

Temp. Control Precision

±1℃

Temperature Sensor

Thermocouple

Power Requirement

220V(-15% ~ 10%)50/60Hz

Max. Power

4kW

Gas Requirement

99.5% purity oxygen≥1MPa

Gas pressure

Oxygen(0.28±0.01)MPa  Total Air Flow≥1MPa

Sample Introduction and Discarding

Manual

Gas Flow Checking

Rotor flow meter adopted Gas flow by visual check

Chemical Reagents

Dehydrite

Humidity

≤85%

Ambient Temperature

(15~30)℃

Operational Control

Windows®-based software on external PC

Operation Cost

Oxygen consumption lowered by intelligent gas supplying system.Desiccant: Dehydrite which is of higher cost

Advance Calculation

Yes

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes

 