SDTGA6000A Thermogravimetric Analyzer (Proximate Analyzer)

SDTGA6000A Thermogravimetric Analyzer (Proximate Analyzer)

Application:
SDTGA6000A can be used to determine the moisture, ash and volatile matter as well as calculation of fixed carbon and calorific value in coal, coke, calcined petrol coke and other solid biomass fuel.
描述一
19 samples+1 blank sample for moisture & ash & volatile matter
描述二
没有此类产品
Product description
Highlights:

19 samples can be loaded once + 1 blank sample position for analyzing the moisture, ash and volatile matter.

Unique sample weighing mode, single sample or batch sample weighing are both available, makes the operation convenient.

③Automatic temperature calibration function is available.

④Flexible software design, test procedure, analysis time, temperature etc. can be customized.

⑤LED displays on furnaces to show real-time balance weight data, it makes the sample weighing more convenient.

⑥Single and dual furnace configurations available.

 

Description

SDTGA6000A

Test index

Moisture, ash and volatile matter

Continuous test in batches

Yes

Standards

ASTM D3173/D3174/D3175/DD7582, ISO 17246, GB/T 30732, GB/T 212, ISO 18123/18122/18134, ISO 11722, ISO 1171

Precision

0.02% RSD (1σ, 1g sample)

Furnace temperature

Room temperature~1000℃

Temperature control precision

±2℃

Temperature resolution

0.1℃

Reproducibility

Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%)Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)

Cooling time required for batches of test

No

Furnace Cooling (forced air/N2)

950 to 500°C<30 min

Balance Resolution

0.0001g

Sample introduction and taking

Automatic

Max. Samples

19 samples + 1 blank sample position

Quantity of sample / test time:

Full indexes for 19 samples< 120 min (Quick method)

Sample weight

0.5 up to 5g

Max. power

4kW

Interface:

RS232

Furnace Heating

Resistance Wound

Temperature Calibration

Standard thermocouple

Temp. control precision

±2℃ (moisture) ±5℃ (ash, volatile matter)

Gas Flow Rate

GB:Moisture:Nitrogen,30~60 times/h Ash:Air 60~120 times/h ASTM:Moisture:Nitrogen or Air 2~4(Furnace Volume /min)volatile matter:Nitrogen 2~4(Furnace Volume /min)

Power requirement

220 V(±10%),50 / 60Hz

Gas requirement

Nitrogen/Oxygen/Compressed Air

Gas Pressure

Air 5 to 6 bar (75 to 90 psi)

Minimum Gas Purity

Air/Nitrogen/Oxygen 99.5%; dry, oil-free

Sample weighing

Under normal temp.

Test Temperature

Moisture 105℃,Ash 815℃,Volatile matter 920℃~950℃ Can be customized

Humidity

<80%

Dimensions

550*590*530mm

Weight

70kg

Operational Control

Windows®-based software on external PC/Windows7/ WindowsXP

Advance Calculation

Yes

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes

 

Corresponding parameter set not found, please add it in property template of background