SDCHNS536 Carbon/Hydrogen/Nitrogen/Sulfur Analyzer

Application:

It is suitable for the determination of carbon, hydrogen, nitrogen and sulfur content in samples in the fields of power plant, coal mine, metallurgy, petrochemical, coal chemical, environmental protection, cement, papermaking, geological prospecting, scientific research institutes, solid/hazardous waste, etc.

Stable and reliable operation, cost-effective, simultaneous determination of carbon, hydrogen, nitrogen, and sulfur elements.
Sundy Sundy

Product description

Standard Configuration

Carbon/hydrogen/nitrogen analyzer, sulfur analyzer, PC

CHN analyzer dimension: 680mm*640mm*996mm

CHN analyzer weight: approx. 160kg

Sulfur analyzer dimension: 760mm*434mm*752mm

Sulfur analyzer weight: approx. 80kg

 

Highlights

1.Powerful and Cost-effective.

①One set of equipment can complete all the tests of four elements of CHNS, and also support individual tests of a single or multiple elements.

②CHN analysis is integrated with automatic sample delivery, experiment, and cyclic testing, which can be completely unattended. 36 samples autoloader with optional expanded capacity for up to 72 samples, and samples can be added/replaced during analysis.

③Sulfur analysis sample loading is by manually, quick and easy to operate, and no complicated mechanical actions.

 

2.Full Process Control and High Precision

①Sample introduction component adopted air curtain design, it can prevent the air into the furnace. and auxiliary by flow equalize unit to avoid sample splashing when dropping, ensure complete combustion of the sample and the test result is accurate.

②Equipped high-performance and precision IR sensor to analysis the carbon and hydrogen element, and can monitoring the combustion situation in real time, accurately judge the end of the combustion, effectively shorten the test time and improve the test accuracy.

③High sensitivity and ultra-low temperature drift diffusion type thermal conductivity cell which with independent and accurate thermostatic control to ensure the thermal conductivity baseline stable.

④Ultra-low drift infrared cell, just need to carry out one drift correction per day.

 

 

3.Short and Reliable Gas Path

Adopted confluence board to integrated the gas path, low dead volume, short gas path and less water vapor residue, accurate and automatic flow control, gas path reliability improved.

 

 

4.Humanized Design, Easy to Operate.

①Easy and convenient to check the gas tightness, only need to click on the software.

 

②The crucible can be replaced from the top, the furnace body is easy to disassemble and assemble, and furnace reagent is easy to replace.

③Optional high-performance touch screen, with multi-functional retractable and foldable holder.

 

5.Low Operating Cost 

High stability IR sensor can be stabilized in short time. Equipped with a helium throttling device, the helium flow is only 0.05L/min before sample introduced and automatic switch to 0.7L/min after sample dropped, more efficiency than competitor and saving operating cost.

 

Specifications:

Description  SDCHNS536
Measuring Range

C(0.005%~100%)
H(0.01%~50%)
N(0.01%~50%)
S(0.01%~50%)

Autoloader CHN: 36/72
S: 1
Analysis time  ≤5min
Sample weight  CHN: 75mg~105mg(recommend:100mg)
S: 100mg~500mg (recommend:100mg)
Power supply  AC 220V±10%, 50/60Hz, 8.5kW
Repeatability C≤0.5%
H≤0.15%
N≤0.08%
S: ≤0.05% (St,d≤1.5%) ≤0.1%(1.50%<St,d≤4%) ≤0.2% (St,d>4%)
Gas required Combustion-supporting: Oxygen, ≥99.5% pure, ≥1MPa
Driving: Nitrogen, 99.9% pure, ≥1MPa
Carrier: Helium, 99.99% pure, ≥1MPa
Standard ASTM D4239,ASTM D5373, ASTM D5291, ISO 16634,AS 1038.6.4,ISO 16948, ISO 29541,
ISO 19579:2006,EN 15407,EN ISO 16948:2015-0,GB/T 30728, GB/T 30733, GB/T25214-2010,
UNI 15104, UNI CEN/TS 15407