SDIS450 Infrared Sulfur Analyzer

Application:

SDIS450 can be used to determine the sulfur content in coal, coke, ash, biomass fuels and other combustibles in the fields of power plants, coal mines, petrochemical, paper & steel factory etc.

50 Samples loaded once.
Product description
Highlights:

High Automation, high test efficiency.
①Analysis time / sample is<2 minutes. Samples can be placed in process of test.
②50 autoloader design, high automation, no need attendance in the whole process. Manual sample introduction is also available.
③Patented technology of combustion gas curtain effectively ensures thorough combustion of sample and no emission of gas. Safe and environmental friendly.
④Filter wool can be replaced automatically, no damage to combustion tube and furnace.
⑤Easy and convenient for gas leakage check, operators only need to click on the software. 
Humanization Design with stable performance.
①Tailored boat shaped crucible can be placed at random.
②Automatic identification of crucibles by locator card, no need coding in advance.
High Precision.
①Specially designed high temperature combustion tube with secondary combustion function, makes sure the samples combust thoroughly.
②Self-developed ultra low drift infrared cell guarantees that only one drift in a working day is enough for accurate test.
Intelligent control.
①Easy to use Windows-based software: It only needs to click the mouse after weighing and placing the samples.
②Easy data handling, real time data can be transmitted by internal network.
③With Ethernet bus communication technology, one PC controls several analyzers.
④Capable of connecting with network and balance by RS232 interface.

Specifications:

DescriptionSDIS450
Test MethodInfrared Absorption
Sulfur Determination Range0.01% – 50%(can be extended to 100%)
StandardsISO 29541,ISO 609,ISO 19579 ASTM D1552, ASTM D3177, ASTM D4239, ASTM D5016, ASTM D5373,GB/T 25214, GB/T 28732, AS 1038.6.3.3, BS 1016
Sulfur Resolution0.001%
Analysis Time/sample< 2 min
Preheating Time≤150min
Max. Quantity of sample50
Sample Weight80 – 500mg(100mg Recommended)
Furnace Temp1250℃ – 1350℃
Heating ElementsSilicon Carbide
Temp. Control Precision±1℃
Temperature SensorThermocouple
Power RequirementAC 220V(-15% ~ 10%)50/60Hz
Max. Power4.5kW
Gas Requirement99.5% purity oxygen≥1MPa
Gas pressureOxygen(0.28±0.01)MPa  Total Air Flow≥1MPa
Sample Introduction and DiscardingAutomatic
Gas Flow CheckingRotor flow meter adopted Gas flow by visual check
Chemical ReagentsDehydrite
Humidity≤85%
Ambient Temperature(15~30)℃
Operational ControlWindows®-based software on external PC
Operation CostOxygen consumption lowered by intelligent gas supplying system.Desiccant: Dehydrite which is of higher cost
Dimensions890*670*650mm
Weight135kg
Advance CalculationYes
Analysis ReportYes
Statistics ReportYes
System MonitorYes