Français Русский Español Deutsch Bahasa Indonesia Tiếng Việt 한국어 ภาษาไทย हिन्दी العربية Português 日本語 English 中文
Solid Biofuels -Method for thedetermination ofcalorific value (rice straw, wheat straw)2026-03-23  view:16

     Standards :CEN/TS 14918 , ASTM E711 , and GB/T 30727


Sample Requirements

1. Particle size ≤ 1mm

2. Sample should be Packed with Lens Paper


Test process

Add a specified amount of distilled water (CEN/TS 14918 and ASTM E711:1ml , GB/T 30727:5ml) to oxygen bomb ,Weigh approximately 0.9-1.1 g of sample into lens paper of known mass and calorific value, wrap it, and place it in a metal crucible. Install the ignition wire or ignition cotton thread, and close the oxygen bomb lid. Fill with oxygen and place the oxygen bomb into the calorimeter. Input the sample weight and lens paper weight, and the instrument will automatically complete the calorific value determination and result calculation.


Test conditions

Oxygen pressure : 3.0 MPa                  

Oxygenation time : ≥15s

Ambient temperature : 23℃                 

Outer tub temperature : 28℃

Inner tub temperature : 26℃               

Water tank temperature : 24℃  

       

      Instrument: SDAC1000 

Test Results

Sample Name

Sample mass (g)

Qb,ad
(J/g)

Mean (J/g)

Range (J/g)

wheat straw

0.9963

16259.71

16273.45

60.10

wheat straw

1.0417

16310.37

wheat straw

0.9641

16250.27

rice straw

1.0128

14165.81

14192.56

55.71

rice straw

0.9931

14221.52

rice straw

1.0403

14190.36

 

 

Sales Contact
tel 0086 731 88112150
fax 0086 731 88134650
email sales@sandegroup.com
Service Contact
tel 0086 731 89864000
fax 0086 731 88134650
email service@sandegroup.com
Copyright©HunanSundy Science and Technology Co., Ltd.